2,559 research outputs found

    Soil moisture by extraction and gas chromatography

    Get PDF
    To determine moisture content of soils rapidly and conveniently extract moisture with methanol and determine water content of methanol extract by gas chromatography. Moisture content of sample is calculated from weight of water and methanol in aliquot and weight of methanol added to sample

    Character of the opposition effect and negative polarization

    Get PDF
    Photometric and polarimetric properties at small phase angles were measured for silicates with controlled surface properties in order to distinguish properties that are associated with surface reflection from those that are associated with multiple scattering from internal grain boundaries. These data provide insight into the causes and conditions of photometric properties observed at small phase angles for dark bodies of the solar system. Obsidian was chosen to represent a silicate dielectric with no internal scattering boundaries. Because obsidian is free of internal scatterers, light reflected from both the rough and smooth obsidian samples is almost entirely single and multiple Fresnel reflections form surface facets with no body component. Surface structure alone cannot produce an opposition effect. Comparison of the obsidian and basalt results indicates that for an opposition effect to occur, surface texture must be both rough and contain internal scattering interfaces. Although the negative polarization observed for the obsidian samples indicates single and multiple reflections are part of negative polarization, the longer inversion angle of the multigrain inversion samples implies that internal reflections must also contribute a significant negative polarization component

    Modulated voltage metastable ionization detector

    Get PDF
    The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration of the constituent and a representative amplitude is applied to another input of said strip chart recorder

    Automatic amino acid analyzer

    Get PDF
    Analyzer operates unattended or up to 15 hours. It has an automatic sample injection system and can be programmed. All fluid-flow valve switching is accomplished pneumatically from miniature three-way solenoid pilot valves

    Gas chromatography: Possible application of advanced instrumentation developed for solar system exploration to space station cabin atmospheres

    Get PDF
    Gas chromatography (GC) technology was developed for flight experiments in solar system exploration. The GC is a powerful analytical technique with simple devices separating individual components from complex mixtures to make very sensitive quantitative and qualitative measurements. It monitors samples containing mixtures of fixed gases and volatile organic molecules. The GC was used on the Viking mission in support of life detection experiments and on the Pioneer Venus Large Probe to determine the composition of the venusian atmosphere. A flight GC is under development to study the progress and extent of STS astronaut denitrogenation prior to extravehicular activity. Advanced flight GC concepts and systems for future solar system exploration are also studied. Studies include miniature ionization detectors and associated control systems capable of detecting from ppb up to 100% concentration levels. Further miniaturization is investigated using photolithography and controlled chemical etching in silicon wafers. Novel concepts such as ion mobility drift spectroscopy and multiplex gas chromatography are also developed for future flight experiments. These powerful analytical concepts and associated hardware are ideal for the monitoring of cabin atmospheres containing potentially dangerous volatile compounds

    Preliminary results of spectral reflectance studies of tycho crater

    Get PDF
    The preliminary analysis and interpretation of near infrared spectra obtained for both the interior and exterior deposits associated with the Tycho crater is presented. Specific objectives were: (1) to determine the composition and stratigraphy of the highland crust in the Tycho target site; (2) to determine the likely composition of the primary ejecta which may be present in ray deposits; (3) to investigate the nature of spectral units defined in previous studies; (4) to further investigate the nature and origin of both the bright and dark haloes around the rim crest; and (5) to compare the compositions determined for the Tycho units with those of the Aristarchus crater as well as typical highland deposits. The spectra obtained for the interior areas exhibit similar spectral features. These include relatively strong 1 micron absorption bands whose minima are centered between 0.97 and 0.99 microns and shallow to intermediate continuum slopes. The spectra generally exhibit indications of a 1.3 micron feature consistent with the presence of Fe(2+) bearing plagioclase feldspar. The strong 1 micron absorption features indicate a dominant high Ca clinopyroxene component. Results obtained from the ejecta deposits show that the spectrum of the inner, bright halo is almost identical with those obtained for interior units. The spectrum of the dark halo exhibits a wide, relatively shallow absorption feature centered at 1.01 microns, a 1.3 micron absorption, and a steep continuum slope. This spectrum is interpreted as indicating the presence of pyroxene, Fe-bearing feldspar, and a significant component of Fe-bearing impact melt glass. Finally, the spectra of spots inside Tycho show similarity with certain spectra for Aristarchus. However, the suite of spectra obtained for Tycho exhibits a different trend in terms of band center versus width

    An electrophoretic karyotype for yeast.

    Full text link

    Chronic dermatomycoses of the foot as risk factors for acute bacterial cellulitis of the leg: A case-control study

    Get PDF
    Objective: To assess the role of foot dermatomycosis ( tinea pedis and onychomycosis) and other candidate risk factors in the development of acute bacterial cellulitis of the leg. Methods: A case-control study, including 243 patients ( cases) with acute bacterial cellulitis of the leg and 467 controls, 2 per case, individually matched for gender, age (+/-5 years), hospital and admission date (+/-2 months). Results: Overall, mycology-proven foot dermatomycosis was a significant risk factor for acute bacterial cellulitis (odds ratio, OR: 2.4; p < 0.001), as were tinea pedis interdigitalis (OR: 3.2; p < 0.001), tinea pedis plantaris (OR: 1.7; p = 0.005) and onychomycosis (OR: 2.2; p < 0.001) individually. Other risk factors included: disruption of the cutaneous barrier, history of bacterial cellulitis, chronic venous insufficiency and leg oedema. Conclusions: Tinea pedis and onychomycosis were found to be significant risk factors for acute bacterial cellulitis of the leg that are readily amenable to treatment with effective pharmacological therapy. Copyright (C) 2004 S. Karger AG, Basel
    • …
    corecore